2025/11/02
Percutaneous Laser Ablation of Tributary Varicose Veins Using a Radial Two-ring Slim Fiber: A Minimally Invasive Alternative to Stab Avulsion from a Japanese Single-Center Experience
- 著者
- Junichi Utoh, MD, PhD
- 掲載誌
- Journal of Vascular Surgery: Venous and Lymphatic Disorders, 14
- 発行年
- 2025
- 要約
-
Objective:
Since the radial two-ring slim fiber became clinically available in 2018, percutaneous laser ablation of tributary varicose veins has gained popularity in Japan. Because it requires no skin incision, this technique offers advantages over stab avulsion by avoiding adverse events such as bleeding, nerve injury, lymphatic damage, and scarring. In October 2024, the procedure was approved for coverage under the Japanese national health insurance system. Subsequently, a national guideline was published in April 2025. This study presents the practical technique and clinical outcomes from a single-center experience in Japan.Methods:
This study included 1213 consecutive cases treated with truncal endovenous laser ablation (EVLA) and adjunctive tributary ablation at our institution for the past 3 years between June 2022 and May 2025. The procedure used an ELVeS 1.27-mm radial two-ring slim fiber (Biolitec) connected to a 1470-nm diode laser. Under ultrasound guidance, tributary veins were punctured using a manually curved 16G venule needle, followed by fiber insertion and ablation. Energy settings were 5 W and a linear endovenous energy density (LEED) of 25 to 30 J/ cm. Stab avulsion was not performed concomitantly. Clinical parameters, adverse events, and occlusion rates were assessed at the 1-month follow-up.Results:
During the study period, 1339 truncal EVLAs were performed, with tributary ablation carried out in 90.6% of cases. The number of puncture/ablation sites per leg ranged from 1 to 32 (mean, 5.3). Operation time ranged from 11 to 64 minutes (mean, 23.3 minutes). Stab avulsion was not concomitantly performed in any cases. All patients could walk home within 15 minutes after EVLA. No skin burns or major nerve injuries were observed. Minor complications occurred in 2.8% of cases, including transient superficial thrombophlebitis and prolonged postoperative pain. Ultrasonography at 1 month confirmed complete occlusion in all treated tributaries.Conclusions:
Previous studies using bare-tip fibers for tributary ablation have reported relatively high complication rates, including skin burns (9%-12%) and nerve injuries (5%-11%). As a result, current Western guidelines do not explicitly recommend laser ablation for tributary varicose veins. In contrast, our experience using a radial two- ring slim fiber demonstrated safety and efficacy. This technique offers a minimally invasive alternative to stab avulsion, especially for patients receiving anticoagulation therapy. Additionally, excellent cosmetic outcomes can be expected, as no skin incisions are required. In 2025, the Japanese Society of Phlebology published a national guideline officially recognizing this technique, recommending low-energy settings (5 W, 25-30 J/cm LEED) and intraluminal fiber placement to minimize adverse events. A formal certification system has also been established in Japan to ensure the safe practice of this procedure."
- キーワードから探す